Patient Monitor User Manual Intended Use and Safety Guidance
- 3 -
WARNING
5 SHOCK HAZARD-Do not attempt to connect or disconnect a power cord with wet
hands. Make certain that your hands are clean and dry before touching a power cord.
6 Accessory equipments connected to the analog and digital interfaces must be
certified according to the respective IEC/EN standards (e.g. IEC/EN 60950 for data
processing equipment and IEC/EN 60601-1 for medical equipment). Furthermore all
configurations shall comply with the valid version of the standard IEC/EN 60601-1.
Therefore anybody, who connects additional equipment to the signal input or output
connector to configure a medical system, must make sure that it complies with the
requirements of the valid version of the system standard IEC/EN60601-1. If in doubt,
consult our technical service department or your local distributor.
7 If the monitor is accidentally damped, place it in the dry circumstance, and do not
operate it until it is approved for further use. If liquid is inadvertently spilled on the
monitor, contact the service personnel authorized by the manufacturer.
8 During monitoring, if the power supply is off and there is no battery for standby, the
monitor will be off. The settings configured by the user can be stored, and settings
not configured by user keep no change. That is, the last settings used will be
recovered when the power is restored.
9 The device and accessories are to be disposed of according to local regulations after
their useful lives. Alternatively, they can be returned to the dealer or the manufacturer
for recycling or proper disposal. Batteries are hazardous waste. Do not dispose them
together with house-hold garbage. At the end of their life hand the batteries over to
the applicable collection points for the recycling of waste batteries. For more detailed
information about recycling of this product or battery, please contact your local Civic
Office, or the shop where you purchased the product.
10 The packaging is to be disposed of according to local or hospitals regulations;
otherwise, it may cause environmental contamination. Place the packaging at the
place which is inaccessible to children.
11 Only patient cable and other accessories supplied by the manufacturer can be used.
The performance and electric shock protection can not be guaranteed, and the
patient may be injured otherwise. Prior to use, check if the casing of a disposable or
sterilized accessory is intact. Do not use it if its casing is damaged.
12 Before using the device, the equipment, patient cable and electrodes etc. should be
checked. Replacement shall be taken if there is any evident defect or signs of aging
which may impair the safety or performance.
13 Be sure that all electrodes have been connected to the patient correctly before
operation.
14 Do not touch the patient and metal part of the monitor when operating the monitor.
15 Do not touch the patient, bed and instrument during defibrillation.
16 Please set the alarm according to the individual status of patient to avoid delaying
treatment. Ensure there will be alarm audio prompt when alarming.