3.10 Motor controller auxiliary connector socket
The pump has a 4-way auxiliary connector socket at the side of the motor controller.
The mang plug for the connector is pre-installed to a number of accessories or
available as an accessory. Refer to Accessories on page 101.
The connector supplies the power to the vent valve or a fan. The connector is shown in
Figure: Valve connector on page 29, with the polarity of the pins marked, when the vent
valve or fan is set to on.
The auxiliary connector output is controlled to 24 V d.c. to control the accessories, even
when the pump is in operaon from a 48 V d.c. supply and is protected from the
overload and short circuits. If the auxiliary load current becomes more than the value
given in Table: Motor controller technical data on page 28, the output will stop to
protect the motor controller.
Table 8
Motor controller technical data
Descripon Data
Connector plug Phoenix part number SACC-DSI-M 8FS-4CON-M12/0.5
Voltage output 24 V d.c. -25%, +10% (18 V d.c. to 26.4 V d.c.)
Current output 500 mA
The motor controller connector gives two independently congured and controlled
outputs:
▪ Aux output 1
It is congured through the vent opon 1 and valve 1 type. Refer to Vent valve
control on page 69.
Aux output 1 has default sengs for a normally open vent valve.
▪ Aux output 2
It is congured through vent opon 2 and valve 2 type. Refer to Vent valve control
on page 69.
Aux output 2 has default sengs for a fan.
This enables the combinaon of fan or vent valve accessory to be connected, congured
and controlled correctly.
The nEXT air coolers and vent valve accessories (which have the corresponding
connector installed) are congured to Aux output 1 and Aux output 2 to give the plug
and play ability (refer to Accessories on page 101). The nEXT vent valves are congured
to Aux output 1 and the default seng for the vent opons 1 are applicable for this type
of accessory. The nEXT85 air coolers are congured to Aux output 2 and the default
seng for the vent opons 2 are applicable for this type of accessory.
Bare wire versions of the nEXT air coolers and vent valve accessories are available, which
are not pre-congured. This enables any combinaon of accessory to be used,
congured independently and controlled on Aux output 1 and Aux output 2.
Page 28
B8G000880_D - Technical data