You can operate the pump using the manufacturer's TIC Turbo Instrument Controller, TIC
Turbo Controller, TAG Controller or by the customer supply and controlled using the
customer system. Refer to Connect the logic interface to the control equipment on page
42 for informaon about control. Refer to Connect the electrical supply on page 43 for
instrucons on how to connect the electrical supply.
4.4.1 Ground the connecons
We recommend you to install a separate ground conductor to ground the pump.
Ground the pump using the given connecon. Refer to Figure: Dimensions - nEXT85
ISO63 on page 18, Figure: Dimensions - nEXT85 CF63 on page 19, Figure: Dimensions -
nEXT85 ISO100 on page 19 and Figure: Dimensions - nEXT85 DN40 on page 19.
Use the braided wire that is not insulated or a separate insulated green / yellow
connector, an M5 x 10 screw and shake proof washer supplied (installed to the ground
hole of the pump) to install the ground connector to the pump. The size and rang of
the ground conductor has to be suciently large to protect against other equipment in
the customer system. The impedance between the pump body and the ground
connecon point must be < 0.1 Ω.
4.4.2 Connect the logic interface to the TIC or TAG
If the manufacturer's TIC Turbo Instrument Controller, TIC Turbo Controller or TAG
Controller is used to power and control the pump, connect the pump logic interface
cable into the back of the TIC or TAG. Refer to the TIC or TAG Instrucon Manuals for
more informaon.
If the TIC or TAG is to be used to control the pump, make sure that the RS485 / RS232
slide switch is in the RS232 posion. Refer to Connect the serial interface to the customer
control equipment on page 45. If the switch is in the RS485 posion:
▪
the TIC will connect to the pump in a parallel mode (that shows the pump type as
nEXTp)
▪ the serial connecon is disabled
▪ start and stop is possible
▪
the TAG will not connect to the pump or control the pump.
4.4.3 Connect the logic interface to the control equipment
If you use your own control system to operate the pump, use an applicable connector
mang half (not supplied) to connect the control equipment to the connector on the
logic interface cable.
Refer to Table: Logic interface connector pins on page 26 for the details of the logic
interface connector pins, when you do the electrical connecons to the pump.
Refer to Table: Logic interface technical data on page 25.