36Installation and Service Guide: Color Controller E-85
Using the E-85
Printable Info menu
This section describes how to print pages such as the Test Page and Configuration page from the Printable Info menu
(described on page 35). The Printable Info menu is accessed through the Fiery tab (see page 35).
Printing the Configuration page can be helpful during installation, Setup, and service. After installing the E-85 (including
connecting to the network), and before default settings are changed in Run Setup, you can obtain a record of the defaults by
printing the Configuration page.
Before you perform any service procedure, you should print the E-85 Configuration page, if possible, so you are prepared
to return the settings to their former configuration, if necessary.
Printing the Test Page indicates that the E-85 is functional and that the connection between the E-85 and the printer is
working.
To print a page from the Printable Info menu
1 If it is not powered on already, power on the printer and allow it to warm up.
2 If it is not powered on already, power on the E-85 using the power button on the front panel and allow it to start up
completely (approximately three minutes).
Note: If the power synchronization is enabled, the E-85 will automatically powers on when you power on the printer.
The default setting for power synchronization is OFF. See “Power synchronization” on page 25 for more information.
3 Make sure that Idle appears on the Fiery Main menu.
If Busy or Printing appears, the E-85 is processing and you must wait until Idle appears.
4 Touch the Fiery tab.
5 Touch Printable Info and then select the page that you want to print.
The E-85 sends the selected page(s) to the printer.
Clear Server Clear all jobs in all server queues, as well as all jobs archived on the E-85 hard disk, the
index of archived jobs (in the Archive window), all FreeForm masters, and the index of
FreeForm masters (in the FreeForm window). Consult with your administrator or operator
before choosing Clear Server.
Restart Fiery Shut down all E-85 activity in the correct manner and then restart. The following options
are available from the submenu that appears:
Restart Fiery Service: Resets the server software but does not reboot the entire system.
Network access to the E-85 is temporarily interrupted and all currently processing jobs are
aborted and may be lost.
Restart System: Shuts down and then reboots the E-85. Network access to the E-85 is
terminated and all currently processing jobs are aborted and may be lost.
Shut Down: Shuts down all E-85 activity properly.