Resistance welder MULTISPOT MI-100control
Troubleshooting
77
Message What’s the problem What should be done?
Who should
do it?
F53
Reduce current by 5 %?
The system has detected that a fuse
was triggered. It is now possible to
reduce the weld current by 5 %.
However, you must
determine yourself whether
the results will be
satisfactory or not. If yes,
confirm.
Operator
F54
You are not authorised for
this menu.
You need a CF card with
lower release level.
The access rights stored on the
current CF memory card do not allow
you to modify these settings.
If you absolute require the
rights, call ELEKTRON
new key file.
Operator
F55
Entry of user identifier
absolutely necessary.
During the configuration of the
welder, it was decided that a user
name must be entered.
see “6.7.1”
F56
Entry of order number
absolutely necessary.
During the configuration of the
welder, it was decided that an order
number must be entered.
see “6.7.1.1” Operator
F57
Current order data?
This message appears after one
hour, if order data has been entered
and the order has not been
concluded yet.
Acknowledge the dialogue.
If necessary, enter data a
second time.
Operator
F59
Faulty welding cannot be
recognised by deactivated
safety routines.
One or several safety rules have
been switched off.
If a problem should occur during
welding, the system cannot adjust.
You must determine
yourself whether the results
will be satisfactory or not. If
yes, confirm.
Operator
F62
Internal flash error.
The internal memory is damaged and
/ or does not contain any data.
Service personnel only. Service
An error occurred while trying to write
data into memory during an update.
F63
File header faulty. Delete
data.
The .elk files of an update are not
compatible with the welder’s current
software. Update will be aborted.
Contact ELEKTRON and
ask for new .elk files. Be
sure to state correct
software version.
Operator
F64
Conflict of versions IO
board / system controller
The software of the control unit and
IO board are not compatible with
each other. This can occur, for
instance, after electronic components
have been replaced.
Service personnel only. Service
F66
Different setting data in I/O
and system board. Restore
data from I/O System Abort.
Comparison of IO board data and
control unit data not successful. The
control unit has a backup file of this
very important data package. So, the
message will always occur after one
of the two components has been
replaced.
Press button “IO” or
“System” to select which
component should be used
to restore the data. Be sure
to select the component
that has NOT been
replaced.
Service