7.2.3 Possible causes and remedies in case of unsatisfactory welding results
Symptom Possible cause Remedy
WHO should
do it?
Weld spot too small Weld current too weak. Adapt welding parameters.
If that doesn’t do it, fall back
on pre-defined programs
and / or keyboard mode.
Operator
Weld time too short.
Wrong welding program. Select correct welding
program.
If in doubt, talk to the
manufacturer and / or OEM.
Operator
Welding spot burns up,
excessive spattering,
sheets not strong enough.
Weld current too high. Adapt welding parameters.
If that doesn’t do it, fall back
on pre-defined programs
and / or keyboard mode.
Operator
Weld time too long.
Wrong welding program. Select correct welding
program. If in doubt, talk to
the manufacturer and / or
OEM.
Operator
Welding job flawed Welding parameters not set correctly
according to requirements.
Use the “Info” button to call
up the values set. Compare
to your specs.
Operator
Sheets may have been insufficiently
prepared.
“6.1.1” Operator
Setting / operating error(s) within the
operating mode set.
“6.4.2” If in doubt,
contact manufacturer.
Operator

Table of Contents