Emotron VSB Instruction Manual Chapter 6 Specification of Parameters
Fig. 6-14
C1-14
Detection width of
frequency attained
Range: 0.00Hz - maximum
FREQ
Factory default:
2.50Hz
This parameter should be set with digital output terminal "frequency attained". When the
difference between output frequency and command frequency is less than this value, terminal
"frequency attained" aoutputs ON. See Fig. 6-15:
Fig. 6-15
时间
输出频率
时间
FDT1电平下限
FDT1
电平上限
FDT1端子
时间
输出
时间
频率到达端子
设定频率
频率检出宽度
Output frequency
FDT1 upper limit
FDT1 lower limit
FDT1 terminal
Time
Time
Output
Command
frequency
Frequency detection width
Time
Frequency attained
terminal
Time