Emotron VSB Instruction Manual Chapter 8 Maintenance
8.4 Storage
Storage environment should meet the requirements as set forth in the table below.
Items Requirements
Recommended storage method and
Storage
-40 to +70 °C
In case of long-term storage, areas with an
ambient temperature of less than 30 °C are
recommended
Avoid the storage in areas where
temperature shock may result in
condensation and freezing
Storage
5 - 95%
Product could be sealed with plastic film and
Storage
A space with low vibration and
low content of salt where there
is no direct exposure to
sunlight, dust, no corrosive or
flammable gas, oil stain, vapor
Product could be sealed with plastic film and
dessicant
ATTENTION:
Since long-term storage may lead to the deterioration of electrolytic capacitor, the inverter
must be powered on once in case storage period exceeds 2 years. During the power-on,
input voltage must be boosted to rated value gradually using a voltage regulator, and be
sure to have the inverter operate at no load for more than 5 hours.
- 159 -