Cerabar M PMC51, PMP51, PMP55
Endress+Hauser 21
FOUNDATION Fieldbus
Version for non-hazardous areas: 9 to 32 V DC
Current consumption
PROFIBUS PA: 11 mA ±1 mA, switch-on current corresponds to IEC 61158-2, Clause 21
FOUNDATION Fieldbus: 16 mA ±1 mA, switch-on current corresponds to IEC 61158-2, Clause 21
Electrical connection
Cable entry Degree of protection Option
1)
M20 gland IP66/67 NEMA 4X/6P A
G ½" thread IP66/67 NEMA 4X/6P C
NPT ½" thread IP66/67 NEMA 4X/6P D
M12 plug IP66/67 NEMA 4X/6P I
7/8" plug IP66/67 NEMA 4X/6P M
HAN7D plug 90 deg IP65 P
PE cable 5m IP66/68 NEMA4X/6P + pressure compensation via cable S
M16 valve connector IP64 V
1) Product Configurator, order code for "Electrical connection"
PROFIBUS PA
The digital communication signal is transmitted over the bus via a 2-wire connection. The bus also
provides the power supply. For further information on the network structure and grounding, and for
further bus system components such as bus cables, see the relevant documentation, e.g. Operating
Instructions BA00034S "PROFIBUS DP/PA: Guidelines for planning and commissioning" and the PNO
Guideline.
FOUNDATION Fieldbus
The digital communication signal is transmitted over the bus via a 2-wire connection. The bus also
provides the power supply. For further information on the network structure and grounding and for
further bus system components such as bus cables, see the relevant documentation, e.g. Operating
Instructions BA00013S "FOUNDATION Fieldbus Overview" and the FOUNDATION Fieldbus Guideline.
Terminals
Supply voltage and internal ground terminal: 0.5 to 2.5 mm
2
(20 to 14 AWG)
External ground terminal: 0.5 to 4 mm
2
(20 to 12 AWG)
Cable entry
Approval Type Clamping area
Standard, CSA GP
ATEX II1/2G or II2G Ex ia,
IEC Ex ia Ga/Gb or Ex ia Gb,
FM/ CSA IS
Plastic M20x1.5 5 to 10 mm (0.2 to 0.39 in)
ATEX II1/2D Ex t, II1/2GD Ex ia,
II3G Ex nA,
IEC Ex t Da/Db
Metal M20x1.5 (Ex e) 7 to 10.5 mm (0.28 to 0.41 in)
For other technical data, see the housing section →  48