Cerabar M PMC51, PMP51, PMP55
Endress+Hauser 23
Devices with M12 plug(Analog, HART, PROFIBUS PA)
2
1
34
A0011175
1 Signal +
2 Not assigned
3 Signal –
4 Ground
Endress+Hauser offers the following accessories for devices with an M12 plug:
Plug-in jack M 12x1, straight
Material: body PA; coupling nut CuZn, nickel-plated
Degree of protection (fully locked): IP66/67
Order number: 52006263
Plug-in jack M 12x1, elbowed
Material: body PBT/PA; coupling nut GD-Zn, nickel-plated
Degree of protection (fully locked): IP66/67
Order number: 71114212
Cable 4x0.34 mm
2
(20 AWG) with M12 socket, elbowed, screw plug, length 5 m (16 ft)
Material: body PUR; coupling nut CuSn/Ni; cable PVC
Degree of protection (fully locked): IP66/67
Order number: 52010285
Devices with 7/8" plug (Analog, HART, FOUNDATION Fieldbus)
4
2
3
1
A0011176
1 Signal -
2 Signal +
3 Not assigned
4 Shield
External thread: 7/8 - 16 UNC
Material: 316L (1.4401)
Protection: IP66/68
Cable specification Analog
Endress+Hauser recommends using twisted, shielded two-wire cables.
The cable outer diameter depends on the cable entry used.
HART
Endress+Hauser recommends using twisted, shielded two-wire cables.
The cable outer diameter depends on the cable entry used.

Table of Contents

Other manuals for Endress+Hauser Cerabar M PMC51