Cerabar M PMC51, PMP51, PMP55
58 Endress+Hauser
PMC51: process connections
with flush-mounted process
isolating diaphragm
China standard flanges, connection dimensions HG/T 20592-2009 (DN-flanges) or HG/T
20615-2009 ("-flanges), raised face RF
A0020955
D Diameter of flange
b Thickness
g Raised face
k Hole circle
g
2
Diameter of hole
d
M
Max. diaphragm diameter
Engineering unit mm
Flange
1)
Boltholes Weight Option
2)
Nominal diameter Class/nominal pressure D b g m Number g
2
k
[mm] [mm] [mm] [mm] [mm] [mm] [kg (lb)]
DN
DN50 40 bar 165 20 102 27.5 4 18 125 3 (6.6) 7HJ
DN80 40 bar 200 24 138 45.5 8 18 160 5.5 (12.13) 7KJ
[in]
2" 150lb./sq.in 150 17.5 92.1 22.55 4 18 120.7 2.2 (4.85) 7PJ
2" 300 lb./sq.in 165 20.7 92.1 22.55 8 18 127 3 (6.62) 7RJ
3" 150 lb./sq.in 190 22.3 127 40 4 18 152.4 4.7 (10.36) 7VJ
3" 300 lb./sq.in 210 27 127 40 8 22 168.3 6.6 (14.55) 7XJ
1) Material: AISI 316L
2) Product Configurator, order code for "Process connection"
PMC51: process connections
with flush-mounted process
isolating diaphragm - height
H
F31 housing F15 housing
94 mm (3.7 in) 98 mm (3.86 in)