EasyManua.ls Logo

Endress+Hauser Proline Promag W 400 - Page 31

Endress+Hauser Proline Promag W 400
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Proline Promag W 400 EtherNet/IP Installation
Endress+Hauser 31
Wall mounting
149 (5.85)
210.5 (8.29)
=
5.8 (0.23)
17 (0.67) =
14 (0.55)
5.8 (0.23)
A0020523
 7 Engineering unit mm (in)
1. Drill the holes.
2. Insert wall plugs into the drilled holes.
3. Screw in the securing screws slightly at first.
4. Fit the transmitter housing over the securing screws and mount in place.
5. Tighten the securing screws.
Post mounting
L
WARNING
Excessive tightening torque applied to the fixing screws on plastic housing!
Risk of damaging the plastic transmitter.
Tighten the fixing screws as per the tightening torque: 2 Nm (1.5 lbf ft)

Table of Contents

Other manuals for Endress+Hauser Proline Promag W 400

Related product manuals