Installing and Removing a Power Supply
Enterasys K-Series K6 Chassis Hardware Installation Guide 3-15
Figure 3-13 Removing a Coverplate from a K-AC-PS-1400W Power Supply Slot
Removing a Power Supply
Wheneverpossible,youshouldinstallareplacementpowersupplybeforeremovingapower
supply.
ToremoveaKACPS1400Wpowersupply:
1. AttachtheantistaticwriststrapasdescribedinAttachingtheElectrostaticDischargeWrist
Straponpage 312beforehandlingthepowersupply.
2. Unplugthepowercordfrom
thededicated ACoutlet.
3. UnplugthepowercordfromtheACpowerconnectorofthepowersupply.
4. Unscrewthecaptivescrewstoreleasethepowersupplyfromthechassis.
5. Graspthepowersupplyhandleandpullthepowersupplystraightoutofthechassis.
6. Placethepowersupplyonanantistaticsurfaceor
inanantistaticbagforfutureuse.
1 Power supply slot 3 Captive screw
2 Coverplate
Caution: If you plan to operate the chassis with only one power supply, make sure to install the
coverplate in place of the removed power supply to reduce Electromagnetic Interference.
Precaución: Si desea trabajar sólo con una fuente de poder, no olvide colocar la tapa en el
compartimiento de la fuente de poder que haya eliminado, para reducir la interferencia
electromagnética.