PoE Port Status LEDs
B-2 About PoE (Power over Ethernet)
PoE Port Status LEDs
ThePoEportstatusofeach10/100/1000MbpsRJ45portonaKSerieslinecardisindicatedbythe
twocolorRXandTXLEDdisplayforeachport.ToobservethePoEportstatusindications,you
mustswitchtheKSerieslinecardfromthedefaultRX/TXStatus
ModetothePoEPortStatus
ModeusingtheredPOEbuttonontheKSeriesfabriccard.
Allocation of PoE Power to Devices
YoucaninstalluptofourKACPS1400WpowersuppliesintheK6chassis.EachKACPS
1400WpowersupplyinstalledintheK6chassisprovidesfrom400watts(at120V)to800watts(at
240V)ofPoEpowertopowereddevices(PDs)attachedtothe10/100/1000Mbps
RJ45portsonthe
installedKSerieslinecards.
ForadditionalPoEpower,youcanconnectoneKACPS1400Wpowersupply,installedinaK
POE4BAYPoEshelf,totheK6chassis.ThisKACPS1400Wpowersupplyalsoprovidesfrom
400watts(at120V)to
800watts(at240V)ofadditionalPoEpowerforpowereddevices(PDs)
attachedtothe10/100/1000MbpsRJ45portsontheinstalled KSerieslinecards.
TheKSeriesfirmwaredeterminesthepoweravailableforPoEbasedonpowersupplystatusand
powersupplyredundancymode.Whenanychangeismade
tothepowersupplystatusor
redundancymode,thefirmwarerecalculatesthepoweravailableforPoE.
ThepoweravailableforPoEisdistributedbasedontheconfiguredallocationmode:
Automaticmode(default),inwhichavailablepowerisdistributedev enly.Anychangein
availablepower,duetoachangeinpowersupply
statusorredundancymode,willtriggeran
automaticredistributionofpower.
Manualmode,inwhichthepowerbudgetismanuallyconfigured,usingeitherCLI
commandsortheMIBs.Thewattageconfiguredcannotexceedthetotalpoweravailableon
theswitchforPoE.
Theconfiguredwattageassignmentisusedtocalculate
thetotalavailablePoEpower.Ifthe
totalavailablePoEpowerchanges,aredistributionofavailablepowerwilloccur,applyingthe
calculatedpercentage.
IfthePoEpowerneededorrequestedexceedsthepoweravailable,thesystemwillgenerateatrap
tonotifythesystemmanager.
Formoreinformationonconfiguringallocationmode,
seetheEnterasysKSeriesCLIReference.
Management of PoE Power to PDs
YoucanconfigurehowtheKSerieschassismakespoweravailabletoattachedPDs:
Realtimemode(default),inwhichthePoEcontrollercalculatesthepowerneededbyaPD
basedontheactualpowerconsumptionoftheattacheddevices.
Classmode,inwhichthePoEcontrollermanagespowerbased
ontheIEEE802.3atdefinition
oftheclasslimitsadvertisedbytheattacheddevices.Inthismode,themaximumamountof
powerrequiredbyadeviceintheadvertisedclassisreservedfortheport,regardlessofthe
actualamountofpowerbeingusedbythedevice.
Formoreinformationon
configuringpowermanagementmode,seetheEnterasysKSeriesCLI
Reference.