EasyManua.ls Logo

Enterasys K6 - PoE Port Status LEDs; Allocation of PoE Power to Devices; Management of PoE Power to PDs

Enterasys K6
78 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PoE Port Status LEDs
B-2 About PoE (Power over Ethernet)
PoE Port Status LEDs
ThePoEportstatusofeach10/100/1000MbpsRJ45portonaK‐Serieslinecardisindicatedbythe
two‐colorRXandTXLEDdisplayforeachport.ToobservethePoEportstatusindications,you
mustswitchtheK‐SerieslinecardfromthedefaultRX/TXStatus
ModetothePoEPortStatus
ModeusingtheredPOEbuttonontheK‐Seriesfabriccard.
Allocation of PoE Power to Devices
YoucaninstalluptofourK‐AC‐PS‐1400WpowersuppliesintheK6chassis.EachK‐AC‐PS‐
1400WpowersupplyinstalledintheK6chassisprovidesfrom400watts(at120V)to800watts(at
240V)ofPoEpowertopowereddevices(PDs)attachedtothe10/100/1000Mbps
RJ45portsonthe
installedK‐Serieslinecards.
ForadditionalPoEpower,youcanconnectoneK‐AC‐PS‐1400Wpowersupply,installedinaK‐
POE‐4BAYPoEshelf,totheK6chassis.ThisK‐AC‐PS‐1400Wpowersupplyalsoprovidesfrom
400watts(at120V)to
800watts(at240V)ofadditionalPoEpowerforpowereddevices(PDs)
attachedtothe10/100/1000MbpsRJ45portsontheinstalled K‐Serieslinecards.
TheK‐SeriesfirmwaredeterminesthepoweravailableforPoEbasedonpowersupplystatusand
powersupplyredundancymode.Whenanychangeismade
tothepowersupplystatusor
redundancymode,thefirmwarerecalculatesthepoweravailableforPoE.
ThepoweravailableforPoEisdistributedbasedontheconfiguredallocationmode:
• Automaticmode(default),inwhichavailablepowerisdistributedev enly.Anychangein
availablepower,duetoachangeinpowersupply
statusorredundancymode,willtriggeran
automaticredistributionofpower.
• Manualmode,inwhichthepowerbudgetismanuallyconfigured,usingeitherCLI
commandsortheMIBs.Thewattageconfiguredcannotexceedthetotalpoweravailableon
theswitchforPoE.
Theconfiguredwattageassignmentisusedtocalculate
thetotalavailablePoEpower.Ifthe
totalavailablePoEpowerchanges,aredistributionofavailablepowerwilloccur,applyingthe
calculatedpercentage.
IfthePoEpowerneededorrequestedexceedsthepoweravailable,thesystemwillgenerateatrap
tonotifythesystemmanager.
Formoreinformationonconfiguringallocationmode,
seetheEnterasysK‐SeriesCLIReference.
Management of PoE Power to PDs
YoucanconfigurehowtheK‐SerieschassismakespoweravailabletoattachedPDs:
• Real‐timemode(default),inwhichthePoEcontrollercalculatesthepowerneededbyaPD
basedontheactualpowerconsumptionoftheattacheddevices.
• Classmode,inwhichthePoEcontrollermanagespowerbased
ontheIEEE802.3atdefinition
oftheclasslimitsadvertisedbytheattacheddevices.Inthismode,themaximumamountof
powerrequiredbyadeviceintheadvertisedclassisreservedfortheport,regardlessofthe
actualamountofpowerbeingusedbythedevice.
Formoreinformationon
configuringpowermanagementmode,seetheEnterasysK‐SeriesCLI
Reference.

Table of Contents