Installing and Removing a Line Card
Enterasys K-Series K6 Chassis Hardware Installation Guide 3-23
Installing a Line Card
ToinstallaK‐Serieslinecard:
1. Ifacoverplateisinstalledinthelinecardslot,loosenthecoverplate’stwocaptivescrews
approximatelyhalfaninch.Pullononeofthecaptivescrewstoremovethecoverplate.See
Figure 3‐21.
Figure 3-21 Removing a Cover Plate from a Line Card Slot
2. Opentheejectorhandleofthelinecard.
Theopen
positionisapproximatelya45°angleawayfromthelinecardfaceplate.Theejector
handlemustbeopenwheninsertingthelinecardtoallowthelinecardtobeinstalled
properly.
Electrical Hazard: Only qualified personnel should perform installation procedures.
Riesgo Electrico: Solamente personal calificado debe realizar procedimientos de instalacion.
Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes und qualifiziertes
Personal vorgenommen werden.
Caution: Failure to observe static safety precautions could cause damage to the K-Series module.
Follow static safety handling rules and wear the antistatic wrist strap.
Do not cut the non-conductive bag to remove the module. Sharp objects contacting the board or
components can cause damage.
Precaución: Si no toma las medidas de seguridad necesarias para evitar descargas de
electricidad estática, es posible que el módulo se dañe. Siga los consejos de seguridad para la
manipulación del producto y no olvide utilizar la pulsera antiestática.
No corte la bolsa antiestática para sacar el módulo. Tenga en cuenta que si algún objeto cortante
entra en contacto con la placa o con los componentes, éstos podrían dañarse.
Note: Slot 10 supports only a four port 10G line card.