Troubleshooting Checklist
Enterasys S-Series Stand Alone (SSA) Hardware Installation Guide 3-5
Power Supply LED
The SSA-FB-AC-PS-A and SSA-FB-AC-PS-B power supplies have a single LED. Table 3-3 describes 
the different states of the power supply LEDs. 
Troubleshooting Checklist
If the SSA switch is not working properly, refer to Table 3-4 for a checklist of problems, possible 
causes, and recommended actions to resolve the problem.
Table 3-3 Power Supply LED Status Definitions
LED Color Status
Green Sufficient power is available to the system.
Off No AC power to the power supply or power supply malfunctioning.
Table 3-4 Troubleshooting Checklist 
Problem Possible Cause Recommended Action
All LEDs are OFF. Loss of power. Ensure the SSA switch was installed properly according to the 
installation instructions in Chapter 2, Installation, and that the 
chassis has power.
No Local 
Management 
Password screen.
Incorrect terminal setup. Refer to the S-Series Configuration Guide for proper setup 
procedures.
Improper console cable pinouts. Refer to Appendix A, Specifications for proper COM port 
pinouts.
Corrupt firmware image or hardware 
fault.
If possible, attempt to download the image to the SSA switch 
again. Refer to Appendix B, Clearing the Persistent Storage or 
System Password for instructions to clear NVRAM.
Cannot navigate 
beyond Password 
screen.
Improper username/ password 
combination entered.
If the username/password combination has been forgotten, refer 
to Appendix B, Clearing the Persistent Storage or System 
Password for instructions on how to clear the password, 
resetting it to the default value of null (blank), using either the 
boot loader clearpassword command or set mode switch 
method.
Cannot contact the 
SSA switch 
through in-band 
management.
IP address not assigned. See Enterasys S-Series Configuration Guide for instructions to 
assign an IP address. 
Port is disabled. Enable port. See the Enterasys S-Series Configuration Guide for 
instructions to enable/disable ports.
Host Port policy and/or management 
VLAN is incorrectly configured, or 
not configured. 
Verify that a management VLAN exists and that it is associated 
with the Host Port.
Refer to the Enterasys S-Series Configuration Guide for 
information about Host Port and management VLAN 
configuration.
No link to device. Verify that all network connections between the network 
management station and the SSA switch are valid and operating.
If the problem continues, contact Enterasys Networks for 
technical support.