10.4.6.2.3.4 Result Page
The following result is shown in the main frame after the OKbutton is pressed.
The format of the indicated page is the same as IPsec/IP Filtering > Importing for Client certificate”.
10.4.6.2.3.4.1 Result
Table 10-138 Result
Note: If the size of a certificate to be imported is larger than 24KBytes, the device is unable to read it and a Web browser error is
shown.
10.4.6.2.3.4.2 Button
Table 10-139 Button
Items
Description
Redirect
from
Import
Top Page
Redirect
from
Warning
Pop-up
Redirect
after
Pressing
Reboot
Network
Button
"Setup complete."
This message is shown when
importing is completed.
Yes
No
No
"Shutting down."
"Restarting communication may take a
few minutes."
"If you want to change the settings,
close the Web Config and check your IP
address. Then enter your IP address in
the browser to restart the Web Config."
This message is shown when
importing and overwriting are
completed.
The network shuts down in order to
update.
No
Yes
Yes
"Invalid password."
This message is shown when the
entered password is invalid.
Yes
Yes
No
"Invalid file."
This message is shown in the
following cases.
- The file uses an incorrect format or
wrong interrelation.
- The file size is greater than the
stipulated range of 5k to 24k. (See
the note.)
- The private key and certificate do
not match.
- Incorrect chain.
Yes
Yes
No
"Invalid date and time."
This message is shown when an
expired certificate is imported, and
the date and time are not set.
Yes
Yes
No
"The certificate has expired. Check if the
certificate is valid, or check the date and
time on the product."
This message is shown when an
expired certificate is imported, and
the date and time are already set.
Yes
Yes
No
"Cannot use the Client Certificates that
include more than three CA certificates."
This message is shown when a server
certificate that includes more than 3
CA-signed certs is imported in
PSCS#12.
Yes
Yes
No
"Private key is required."
This message is shown when a
private key is required.
Yes
Yes
No
"Setup failed."
This message is shown when
importing fails.
Yes
Yes
No
"Setup failed."
"Click [Reboot Network] to apply the
settings."
"Communication will be shut down
temporarily."
"The setting may be applied to the
communication after other settings are
changed or the device is restarted."
This message is shown when a
network reboot fails.
No
Yes
Yes
Items
Description
Condition
"Reboot Network"
Reboots the network
If the network reboot is successful, Web Config displays the
successful result page.
If the network reboot fails, Web Config displays the same
page.
If the network reboot fails

Table of Contents

Other manuals for Epson TM-P20II

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Epson TM-P20II and is the answer not in the manual?

Epson TM-P20II Specifications

General IconGeneral
BrandEpson
ModelTM-P20II
CategoryPrinter
LanguageEnglish

Related product manuals