EPSON WF-C5790/WF-C5790a/WF-C5710/ET-8700/WF-C5210/WF-C5290/WF-C5290a Revision A
Disassembly/assembly Disassembly/Reassembly Procedures 349
Confidential
Relay Board Assy
3. Disconnect the cables and FFCs from all connectors on the Relay Board Assy.
4. Remove the grounding cable from the Frame.
5. Remove the four screws (S4: x2, S5: x2), then remove the Relay Board Assy.
No. Screw Type
S4
C.B.P-TITE-SCREW-3x10-F.ZN-3C
S5
C.B.S-TITE-SCREW-3x6-F.ZN-3C
Relay Board Assy
Grounding cable
Relay Board Assy
6. Remove the four screws (S5: ), and remove the Relay Board from the Shield Plate.
No. Screw Type
S5
C.B.S-TITE-SCREW-3x6-F.ZN-3C
Shield Plate
Relay Board