EPSON WF-C5790/WF-C5790a/WF-C5710/ET-8700/WF-C5210/WF-C5290/WF-C5290a Revision A
Disassembly/assembly Disassembly/Reassembly Procedures 499
Confidential
Housing Upper
1. Remove the six screws (S4: ), then remove the Housing Upper.
No. Screw Type
S4
C.B.P-TITE-SCREW-3x10-F.ZN-3C
Top
Panel Assy
When disconnecting the FFC, make sure to unlock the connector lock beforehand.
1. Disconnect the FFC from the connector (CN42) on the Main Board Assy.
2. Peel off the FFC from the Frame Base.
3. Release the FFC from two tabs on the Frame Base.
Set the ferrite core of the FFC in the point shown above.
Ferrite core
FFC
CN42
Main Board
Assy
Double-sided tape
Tab
Connector lock