12 Alarms / Warnings / Errors
Caused by Reason Type Example / Solution
ALD eedback from ALD via ErrorCodes AISG-/VSC-/Other Error (due to AISGSpec,
other Error if there is something wrong
recognized)
After e�g� Calibrate Black screen with
info “AISG Error – MOTOR_JAM”
ALD Feedback from ALD via Alarms Alarm all Alarms are displayed here: AISG-
Alarms + internal ALC Alarms
Alarm: MOTOR_JAM
ALC
Internal
Alarms
Feedback from ALC via Alarms INCOMPATIBLE_STANDARD_VERSION Unsupported AISG Protocol Version
ALC
Internal
Alarms
Feedback from ALC via Alarms CONNECTION_PROBLEMS ALD does not respond to poll frames <=
still connected?
ALC
Internal
Alarms
Feedback from ALC via Alarms COLLECT_DATA_WARNING ALD delivers wrong/uncomplete data at
collect-datarequest
ALC Crash internal Apps Endless Spinner Enter power save mode, see section 6�1
ALC Crash internal Apps Heavy Error – Restart ALC Black screen with info Heavy Error
Restart ALC
ALC Crash internal Apps Connection failed AIAX Error 501 Reload
page
Black screen with info Connection failed
AIAX Error 501 Reload page� Enter
power save mode, see section 6�1
ALC Display Touch is not working Restart ALC