Summa Series Servodrive Product Manual
CiA402 Drive Profile
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
6-79
Index
Subindex
Name
Access
Data Type
Unit
Range
Default
60BC
00
TouchProbePos2PosValue
RO
INT32
60BDh: TouchProbeNeg2PosValue
This object gives the latched position of the falling edge for touch probe 2.
Index
Subindex
Name
Access
Data Type
Unit
Range
Default
60BD
00
TouchProbeNeg2PosValue
RO
INT32
Pn331, Pn332
You can allocate the touch probe functions by Pn331, and set Touch Probe Digital Input Filtering Time by
Pn332. The relevant parameters are as following:
NO.
Name
Range
Unit
Default
When Enabled
Pn331.0
Touch Probe 1 signal
Allocated Pin Number
0 to 2
0
After restart
Pn331.1
Touch probe 2 Signal
Allocated Pin Number
0 to 2
1
Pn332
Touch Probe Digital Input
Filtering Time
0 to 1000
10 ns
0
Immediately
Pn333
You can select whether to invert the Touch Probe 1 and Touch Probe 2 signals through the parameter
Pn333. In General, it needs to be set according to the actual input signal level.
Parameter
Setting
Meaning
When Enabled
Pn333.0
0
Do not invert Touch Probe 1 signal (take effective
when low level)
After restart
1
Invert Touch Probe 1 signal (take effective when
high level)
Pn333.1
0
Do not invert Touch Probe 2 signal (take effective
when low level)
1
Invert Touch Probe 2 signal (take effective when
high level)