Summa Series Servodrive Product Manual
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
Touch probe 1 is disabled.
Touch probe 1 is enabled.
No latched position of the rising edge is stored for touch probe 1.
A latch position of the rising edge is stored for touch probe 1.
No latched position of the falling edge is stored for touch probe 1.
A latch position of the falling edge is stored for touch probe 1.
Record the number of the touch probe 1 executions in the Continuous Trigger
Mode. Values are cycled between 0 and 3.
Touch probe 2 is disabled.
Touch probe 2 is enabled.
No latched position of the rising edge is stored for touch probe 2.
A latch position of the rising edge is stored for touch probe 2.
No latched position of the falling edge is stored for touch probe 2.
A latch position of the falling edge is stored for touch probe 2.
Record the number of the touch probe 2 executions in the Continuous Trigger
Mode. Values are cycled between 0 and 3.
60BAh: TouchProbePos1PosValue
This object gives the latched position of the rising edge for touch probe 1.
60BBh: TouchProbeNeg1PosValue
This object gives the latched position of the falling edge for touch probe 1.
60BCh: TouchProbePos2PosValue
This object gives the latched position of the rising edge for touch probe 2.