Summa Series Servodrive Product Manual
Appendix
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
12-3
No.
Index
Name
Range
Unit
Default
When Enabled
Pn002
3166
Application Function
Selections 2
0000 to 0100
0000
After restart
Pn002.0: Reserved setting (Do not change).
Pn002.1: Reserved setting (Do not change).
Pn002.2: Usage of Absolute Encoder
0
Use the encoder as an absolute encoder.
1
Use the encoder as an incremental encoder.
Pn002.3: Reserved setting (Do not change).