Summa Series Servodrive Product Manual
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
Application Function
Selections 3
Pn003.0: Motor Stopping Methods for Gr.1 Alarms, Servo OFF, STO,
and Servo OFF
Applying the dynamic brake and then let the Motor coast.
Applying the dynamic brake and then place the Motor in DB state.
Coast the Motor to a stop.
Pn003.1: Motor Stopping Method for Overtravel
Applying the dynamic brake and then let the Motor coast.
Coast the Motor to a stop.
Applying the reverse brake and then place the Motor in zero
clamping state.
Applying the reverse brake and then let the Motor coast.
Pn003.2: Reserved setting (Do not change).
Pn003.3: Overload Enhancement
Enabled. This function can enhance the Motor load for
instantaneous more than 2 times rated load, which can be used in
the conditions that require frequent start and stop.
This setting is unavailable for EM3A Motors.