Digital Output Signal Inverts
Pn516.0: CN1-6, 7 inverse selection
The signal is not inverted.
Pn516.1: CN1-8, 9 inverse selection
The signal is not inverted.
Pn516.2: CN1-10, 11 inverse selection
The signal is not inverted.
Pn516.3: CN1-12, 13 inverse selection
The signal is not inverted.
Torque Reaches Status
Detection Torque Threshold
When the torque output exceeds the setting of Pn529 and the time is greater than the setting of Pn530, the
/TCR (Torque Limit Detection Output) signal turns ON.
Torque Reaches Status
Detection Time Threshold
When the torque output exceeds the setting of Pn529 and the time is greater than the setting of Pn530, the
/TCR (Torque Limit Detection Output) signal turns ON.
Discharging Resistor
Resistance
To set the resistance value for the braking.
This setting is not reset when the default setting is restored.
The default settings are as following:
ED3S-A5A* to ED3S-10A*: 50Ω
ED3S-15A*: 40Ω
ED3S-20A* and ED3S-30A*□□: 20Ω