Discharging Resistor Power
To set the power value for the braking resistor.
This setting is not reset when the default setting is restored.
The default setting are as following:
ED3S-A5A* to ED3S-04A*: 40W
ED3S-08A* and ED3S-10A*: 60W
ED3S-15A*: 80W
ED3S-20A* and ED3S-30A*: 150W
Momentary Power Interruption
Hold Time
Even if the main power supply to the Drive is interrupted momentarily, power supply to the Motor (servo
ON status) will be maintained for the time set by this parameter.
The setting is a number of periods, and the time of one period depends on the setting of Pn007.3:
Pn007.3=0, the time of one period is 1/50s.
Pn007.3=1, the time of one period is 1/60s.
Current Threshold for
Detecting Abnormal Operation
Set a percentage threshold for the current to detect that the Motor has been operating abnormally.
Acceleration Threshold for
Detecting Abnormal Operation
Set a threshold for the acceleration to detect that the Motor has been operating abnormally.
To set the device node number in EtherCAT communication.
Mapping to the object 6098h in CiA402.
Speed during Search for
Switch
Mapping to the object 6099-01h in CiA402.
Speed during Search for Zero
Mapping to the object 6099-02h in CiA402.
Mapping to the object 609Ah in CiA402.