Summa Series Servodrive Product Manual
Document Version: V1.01
(Dec, 2019)
© 2019 ESTUN Automation Co., Ltd. All right reserved.
Corrected maximum position limit = Max position limit – Home offset (607Ch)
The software position limits are enabled at the following times:
When homing is completed
When an absolute encoder is connected
The software limits are enabled if Min position limit < Max position limit.
-2147483648 to
2147483647
Max Profile Velocity (607Fh)
This object defines the maximum speed during a Profile Mode operation.
However, the Servo will regard the minimum value between 607Fh and 6080h as the maximum speed
during a Profile Mode operation.
Default: read
from the Motor
Unit: 0.1 rpm
Max Motor Speed (6080h)
This object defines the maximum speed for protecting the Motor.
0 to rated speed
Default: read
from the Motor
Unit: 1 rpm
Profile Velocity (6081h)
This object contains the final movement speed at the end of acceleration for a Profile Mode operation.
0 to 200000
Default: 10000
Unit: 0.1 rpm