DMP 128 Plus • Audio Control Panels 99
Panel ID #
Panel ID numbers (ID #) are used to identify ACP panels connected to the DMP 128 Plus
and are necessary for the panel to function. The ID# is set using the DIP switch assembly
on the physical ACP panel. Once the panel ID has been set on the physical device, the
ID is selected in the Configure ACPs dialog box when the panel is being configured in
DSPConfigurator (for information on how to set the panel ID #, see the corresponding ACP
panel setup guide).
ACP Panel Button Control Types
Click on a button or rotary control within the panel image to select that button for
configuration. When selected, the button or control will turn yellow to indicate that it is
active for configuration, and the Configure ACPs dialog box will populate with a series of
drop-down lists for that purpose. First, one of the following control types must be selected:
• Action-Fixed
• Action-Follow Selector
• Selector-Vol/Mute
There are two basic control types: Action and Selector. Action controls can be either
Action-Fixed or Action-Follow Selector. A button with dedicated functionality, such as a
rotary knob or dedicated volume or mute buttons, can only be configured as an Action
control type.
Action-Fixed
Buttons configured with the Action-Fixed control type perform an action that is tied to a
fixed group, preset, or macro, and is not affected by or dependent on selections made on
other buttons. When Action-Fixed is selected, the Configure ACPs dialog populates with
a series of drop-down list selections shown in the table below. When a selection is made in
the Action list, the Configure ACPs dialog then populates with subsequent selections.
Action Select 1 Select 2 LED Behavior
Group Mute On Mute Master — Reflects Current State
Group Mute off Mute Master — Reflects Current State
Group Mute Toggle Mute Master — Reflects Current State
Group Volume Down Volume Master — Reflects Current State
Group Volume Up Volume Master — Reflects Current State
Group Vol Rotary
(ACP 100 only)
Volume Master — Reflects Current State
Preset Recall Preset — Reflects Current State
Preset Toggle Preset 1 Preset 2 Lit press/Unlit release
Toggles Lit/Unlit
Macro Trigger Macro — Lit press/Unlit release
Macro Toggle Macro 1 Macro 2 Lit press/Unlit release
Toggles Lit/Unlit
Figure 164. Action-Fixed Selection Table
figure 164 Action-Fixed Selection Table