DMP 128 Plus • Dante Controller 117
Redundant Configuration
In redundant mode, the 4-port AT switch acts as two separate 2-port switches that
duplicate audio traffic. Ports 3 and 4 are marked (PRI) for primary while ports 1 and 2
are marked (SEC) for secondary (see figure 187 below). Primary and secondary switches
cannot be connected together anywhere in the audio network. Redundant configuration can
be enabled using Dance Controller or DSP Configurator.
100-240V 0.7A MAX
50 - 60 Hz
LAN
DMP 128 Plus C AT
INPUTS
RxTx G
RS-232
+S+V -S G
GIN
1
O1 O2 GIN
2
O1 O2 GIN
3
O1 O2 GIN
4
O1 O2 GIN
5
O1 O2 GIN
6
O1 O2 GIN
7
O1 O2 GIN
8
O1 O2
56
78
11 12
1 2
3
4
9
10
1 2 3
4 5 6 7 8
I/O
OUTPUTS
DMP EXP
ACP
REMOTE
USB AUDIO
RESET
AT
1
(SEC)
2
3
4
(PRI)
Secondary PortsPrimary Ports
Figure 187. Primary and Secondary AT Ports
To configure the DMP 128 Plus in redundant mode using Dante Controller:
1. Open Dante Controller.
2. Press <Ctrl+D> on the keyboard to access the Device View dialog box.
3. Select the desired DMP 128 Plus AT from the (Choose a Dante Device...)
drop-down menu (see figure 188,
1
below).
4. Select the Network Config tab (
2
).
5. From the Dante Redundancy panel, use the drop-down to select Redundant (
3
).
Figure 188. Redundant Mode Configuration in Dante Controller
figure 187 Primary and Secondary Ports
figure 188 Redundant config in Dante Cont