DMP 128 Plus • Audio Control Panels 103
14. From the panel graphic on the left side of the dialog box, select the VOL knob (see
figure 168,
1
below).
15. From the Control Type drop-down (
2
), choose Action-Follow Selector.
Figure 168. Rotary Volume Knob Configuration
The ACP 100 panel is now fully configured. From this point, either:
Add additional ACP panel configurations.
Save the ACP panel configuration to the DSP Configurator configuration file (see Saving
and Pushing ACP Configurations on page106).
Push the configurations to the DMP 128 Plus (see Saving and Pushing ACP
Configurations on page106).
ACP 106 Style Configuration Example
1. From the DMP 128 Plus main workspace in DSP Configurator, select
Tools > Configure ACP Panels. The Configure ACPs dialog box opens.
2. Select an empty tab from the top of the dialog box to build a new configuration (see
figure 169,
1
below).
3. From the ACP Panel Type drop-down (
2
), select the ACP 106 model to be
configured. The Configure ACPs dialog box populates with a graphic of the selected
ACP 106.
4. From the ID # drop-down (
3
), select the ID number that corresponds with the bus ID
set on the ACP 106 DIP switch assembly (see the ACP 106 D Setup Guide or the ACP
106 EU/MK Setup Guide for information on setting the bus ID #).
Figure 169. Selecting ACP 106 for Configuration
figure 168 Rotary Volume Knob Configuration