EasyManua.ls Logo

Extron electronics DMP 128 Plus - Page 144

Extron electronics DMP 128 Plus
187 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DMP 128 Plus • Remote Control and Configuration 136
Command ASCII command
(host to device)
Response
(device to host)
Additional description
Reboot Commands
Reboot system
E1BOOT} Boot1]
Reboot network
E2BOOT} Boot2]
Serial Host Control Port Mode
Standard host control
(SIS)
EX!*1HSTM} HstmX!*1]
Device control (no SIS)
EX!*2HSTM} HstmX!*2]
Disable port
EX!*0HSTM} HstmX!*0]
Query port mode
EX!HSTM} X8%]
Ping
Execute test
E{address/name}
PING}
{address}*{bytes}*
{ttl}*{time}]
Example:
E192.168.254.254
PING}
192.168.254.254*64*
64*3.469
If ping fails to get reply
from address
{address}*0*0*0]
Timezone and Daylight Settings
Set time zone
E{zone name}*
TZON}
Tzon{zone name,
description}]
View current time zone
ETZON}
{zone name,
description}]
List all time zones
E*TZON}
{zone name,
description}]
...]
...]]
NOTES:
X!
= Port Number 01 (always 01 for DMP 128 Plus)
X8%
= Port Mode 0 = disabled, 1 = standard, 2 = device

Table of Contents