DMP 128 Plus • DSP Configurator Software 29
AEC Operation
Double-click the AEC block to open the AEC drop-down menu. Select AEC to insert the AEC
processor.
Figure 51. AEC Block and Drop-Down Menu
NOTE: Insert the AEC processor on the input with the near end microphone connected.
Once the AEC processor is inserted, double-click the AEC block to open the AEC dialog box.
1
Activity Panel
7
Bypass Button
2
ERL Meter
8
OK Button
3
ERLE Meter
9
Cancel Button
4
TER Meter
¢
Show/Hide Advanced Options Button
5
Reference Selection Drop-Down
£
AEC Help Button
6
Noise Cancellation Panel
Figure 52. AEC Dialog Box