EasyManua.ls Logo

FAAC A1400 AIR RDT - 12.1 Electronics Module (Continued)

FAAC A1400 AIR RDT
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A1400 AIR RDT 52 532119 04 - Rev. C
0.0
RESET/SETUP
DL2
DL11
MAIN
F1
USB
+
-
F
ERR
BAT1
OPEN
EMERG
BAT2
SIC
_
OP
SIC
_
CL
J10
J14
J11
J12
J13
V G
I
I+
I-
J5
V G
E
E+
E-
J6
V G
S1
G
T
J1
V G
S2
G
T
J2
V G
S3
G
T
J3
V G
S4
G
T
J4
J17
V RX TX G
J8
E1 G E2
J7
T1 G
T2
R1
G R2
J9
V G 01 02 02
J22
J21
V
G
I1
I2
G
I3
I4
V
J18
G CH CL G
J23J24
J25
71
DL3
DL6
DL8
DL10
DL7
DL9
DL2
DL5
DL1
DL11
DL4
Translation of the original instructions
ENGLISH
Name Description Statuses
DL1 main
(BLUE) MAIN: main power supply unit input * main power supply ON main power supply OFF
DL2
(BLUE) +5V: board power supply * present absent
DL3
(GREEN) USB: storage device device present * device absent
DL4
RED
ERR: Error/Alert in progress
error * no error/alert
indication
DL5
RED BATT1: battery status
flat battery * battery charged
battery use flat battery with no mains power supply
DL6
(GREEN) BATT2: battery charger activity
battery charger at rest
battery charger not working due to mains
power down or fault
battery charger working
DL7
RED SIC_OP: safety on opening
input active (sensors busy) * input not active (sensors not busy)
DL8
RED SIC_CL: safety on closing
DL9
(GREEN) EMERG: emergency
input active
(door opened in emergency)
* input not active
DL10
(GREEN) OPEN: open button input active (Open impulse) * input not active
DL11
(BLUE)
VACC: accessories power supply (+ 24V ) * present absent
LED statuses:
on flashing * = standby condition
off in sleep:off with blinking every 5 s
10 LED on the board

Table of Contents

Related product manuals