Translation of the original instructions
ENGLISH
MENU 1 LANGUAGE
Default: ITALIANO
-
16 Night-time
-
17 Manual
3. If the input has not been disabled, select the logic:
- Normally open (NO)
- Normally closed (NC)
4. If an input with CLOSURE SAFETY function has been selected, set
the TEST:
- Enabled
- Disabled (Default)
5. Repeat the procedure for the other inputs.
2 Outputs O1 / O2
1. Select an output. The complete list with relevant default is:
- O1 Gong
- O2 Door not closed
2. Select function:
- 0 Disabled
- 1 Gong
- 2 Error
- 3 Battery
- 4 Emergency active
- 5 Test (for I1,I2,I3 and I4)
- 6 Door not closed
- 7 Door open
- 8 Door in motion
- 9 Light*
- 10 Intrusion active
(
*
) If this function is selected, set the time:
- from 1s to 255s (Default 60s)
3. If the output has not been disabled, select the logic:
- Normally open (NO)
- Normally closed (NC)
4. Repeat the procedure for the other output.
3 Safety devices S1-S4
1. Select a SAFETY input. The complete list with relevant default is:
- S1 DISABLED
- S2 DISABLED
- S3 CLOSING SAFETY / TEST ENABLED / NC
- S4 CLOSING SAFETY / TEST ENABLED / NC
2. Select function:
- Disabled
- Closing safety
- Opening safety
3. If the input has not been disabled, set the TEST:
- Enabled
- Disabled
4. If the input has not been disabled, select the logic:
- Normally open (NO)
- Normally closed (NC)
5. Repeat the procedure for the other inputs.
4 Sensors I / E
1. Select a sensor. The complete list with relevant default is:
- SENSOR I Internal current
- SENSOR E External contact NO
2. Select the function for Sensor I (Internal Sensor):
- Internal current
- Internal frequency
- Disabled
3. Select the function for Sensor E (External Sensor):
- Disabled
1
LANGUAGE
MENU 2 PROGRAMMING
The menu is only accessible if the INSTALLER password has been
entered.
If a different password has been inserted, it is indicated: MENU
RESERVED FOR INSTALLERS.
The list is:
- 1 INPUTS / OUTPUTS
- 2 MOTION
- 3 TIMING
- 4 ENERGY SAVING
- 5 BATTERY KIT
- 6 MOTOR BLOCK KIT
- 7 INSTALLATION
- 8 SUNDRIES
- 9 LOG
■
INPUTS / OUTPUTS
OK
OK
INPUTS / OUTPUTS
2
PROGRAMMING
1 Inputs I1- I4
1. Select an input. The complete list with relevant default is:
- I1 OPEN AUTOMATIC / NO
- I2 OPEN EXTERNAL / NO
- I3 KEY / NO
- I4 OPEN SEMI-AUTOMATIC / NO
2. Select function:
-
0 Disabled
-
1 Open total
-
2 Open external
-
3 Exit only
-
4 = Open automatic
-
5 = Open semi-automatic
-
6 Pharmacy
-
7 Key
-
8 Closure safety
-
9 Open internal
-
12 Timer
-
13 Partial
-
14 Opening safety