A1400 AIR RDT 80 532119 04 - Rev. C
Translation of the original instructions
ENGLISH
17. LKEVO
17.1 ASSEMBLY AND TESTING
1. To disassemble the parts LKEVO it is required to leverage points 90-
with a slotted screwdriver.
2. Break off the cable run insert.
3. Mark points on the wall 90-
and fasten the support with adequate
screws.
F
BEFORE CONNECTING THE DEVICE, disconnect the power supply and the
emergency battery of the automation.
4. Connect to board E1400 RD 90-
5. Connection must be carried out with 4- twisted pairs cable
U/UTP
CAT.5 4x2xAWG24
with section 0.5mm 90-
. Maximum dis-
tance is 50 m.
6. Assemble the parts LKEVO with a slight pressure on points 90-
.
!
* It is obligatory to perform a connection on LKEVO on terminals G
and K with key command to block function keys. With NC contact
the keypad is blocked 90-
.
TOTAL TWO-DIRECTION AUTOMATIC
DOOR OPENED
AUTOMATIC TOTAL
ONE-DIRECTIONAL
AUTOMATIC PARTIAL
TWO-DIRECTIONAL
NIGHT
MANUAL
17.2 SELECTION MENU
1. To access the selection menu of the operation mode, press the
corresponding function button.
2. The following functions may be set with the selection buttons:
- TOTAL TWO-DIRECTION AUTOMATIC
- DOOR OPENED
- TOTAL ONE-DIRECTION
- AUTOMATICPARTIAL TWO-DIRECTION AUTOMATIC
- NIGHT
- MANUAL
3. The LED switches on to identify the active function.
4. To switch to another function press the key corresponding to
the new function
.
If the configured inputs are used to override an operating mode,
the LKEVO might have blocked function keys.
89
J8
E1400 RD
LKEVO
8
90
3
3
4
2
1
1
1
TX RX G K G V
7
V
V RX
RX
TX
TX
G
G
U/UTP CAT.5
4x2xAWG24