A1400 AIR RDT 93 532119 04 - Rev. C
Translation of the original instructions
ENGLISH
10 Test Error
Enables/disables movement at slower speed in the event of TEST
ERROR on safety devices.
- ENABLED
- DISABLED (Default)
■
9 LOG
OK
OK
LOG
2
PROGRAMMING
MENU NOT AVAILABLE
MENU 3 ERRORS
OK
OK
OK
OK
01 BOARD FAULT
3
ERRORS
02.....................31
39 OBST. CONS.
OPENING
The display shows current errors:
- 1 Board Failure
- 2 Board E2PROM fault
- 3 Motor_1 driver failure
- 4 VACC anomaly
- 5 Micro-controller error
- 6 VMOT anomaly
- 7 MOT1 motor fault
- 8 AUX motor opening failed
- 9 Mains power supply V main absent
- 10 Battery down or not connected
- 11 S1 test failed
- 12 S2 test failed
- 13 S3 test failed
- 14 S4 test failed
- 15 Data in setup memory not present or corrupted
- 16 Encoder fault
- 17 Inputs fault
- 18 FW not compatible
- 19 High mechanical friction
- 20 Input configured as safety devices test failed
- 21 Low speed opening.
- 22 Corrupted data
- 23 Power supply unit fault
- 24 Consecutive obstacles in closing
- 25 AUX_Motor faulty
- 26 Motor block fault
- 27 Motor_1 rotation error
- 28 AUX_Motor rotation error
- 29 AUX+Motor board fault
- 30 Serious error
- 31 Consecutive obstacles in opening
- 39 Board data being deleted
OK
OK
OK
200 UC FAILURE
3
ERRORS
201...................221
222 TEST VMAIN
1 ERRORS
2 AUX ERRORS
OK
The display shows current errors:
- 200 UC Failure (Corrupted FW or Corrupted RAM)
- 201 Aux Mot Fault
- 202 High Friction
- 203 Aux Mot Driver
- 204 FW Not Compatible
- 205 Motor Rotation
- 206 Encoder Fault
- 216 Communication
(Communication problem between the 2 boards)
- 217 Incorrect Opening Position
- 218 Obstacle
- 219 Incorrect ID
- 220 Vmain
- 221 Timeout
- 222 Test Vmain
MENU 4 INDICATIONS
OK
OK
OK
OK
41 TIME LOSS
4
WARNINGS
42.....................79
80 NON STANDARD
PROGRAM.
The display shows current alerts:
- 41 Date and time loss
- 42 Clock battery flat or absent
- 44 Emergency active
- 45 TIMER active (indicated with T in HOME PAGE)
- 46 Timer function in progress
- 47 Last motion run with battery
- 48 Night-time mode operation
- 49 Manual mode operation
- 50 Partial mode operation
- 51 Obstacle in closing
- 52 Obstacle in opening
- 53 Number of maintenance cycles corrupted on E2prom
- 54 Motor block fault
- 55 Pharmacy mode operation
- 56 Battery operation
- 57 Searching for strike on opening
- 58 Searching for strike on closing
- 59 Motor block anomaly (only with monitoring KIT)
- 60 Requested maintenance
- 61 SDK EVO anomaly
- 62 Faulty battery charger