EasyManua.ls Logo

FAAC A1400 AIR RDT - 10 Test Error Function; Menu 3 Errors; Menu 4 Indications (Alerts)

FAAC A1400 AIR RDT
118 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A1400 AIR RDT 93 532119 04 - Rev. C
Translation of the original instructions
ENGLISH
10 Test Error
Enables/disables movement at slower speed in the event of TEST
ERROR on safety devices.
- ENABLED
- DISABLED (Default)
9 LOG
OK
OK
LOG
2
PROGRAMMING
MENU NOT AVAILABLE
MENU 3 ERRORS
OK
OK
OK
OK
01 BOARD FAULT
3
ERRORS
02.....................31
39 OBST. CONS.
OPENING
The display shows current errors:
- 1 Board Failure
- 2 Board E2PROM fault
- 3 Motor_1 driver failure
- 4 VACC anomaly
- 5 Micro-controller error
- 6 VMOT anomaly
- 7 MOT1 motor fault
- 8 AUX motor opening failed
- 9 Mains power supply V main absent
- 10 Battery down or not connected
- 11 S1 test failed
- 12 S2 test failed
- 13 S3 test failed
- 14 S4 test failed
- 15 Data in setup memory not present or corrupted
- 16 Encoder fault
- 17 Inputs fault
- 18 FW not compatible
- 19 High mechanical friction
- 20 Input configured as safety devices test failed
- 21 Low speed opening.
- 22 Corrupted data
- 23 Power supply unit fault
- 24 Consecutive obstacles in closing
- 25 AUX_Motor faulty
- 26 Motor block fault
- 27 Motor_1 rotation error
- 28 AUX_Motor rotation error
- 29 AUX+Motor board fault
- 30 Serious error
- 31 Consecutive obstacles in opening
- 39 Board data being deleted
OK
OK
OK
200 UC FAILURE
3
ERRORS
201...................221
222 TEST VMAIN
1 ERRORS
2 AUX ERRORS
OK
The display shows current errors:
- 200 UC Failure (Corrupted FW or Corrupted RAM)
- 201 Aux Mot Fault
- 202 High Friction
- 203 Aux Mot Driver
- 204 FW Not Compatible
- 205 Motor Rotation
- 206 Encoder Fault
- 216 Communication
(Communication problem between the 2 boards)
- 217 Incorrect Opening Position
- 218 Obstacle
- 219 Incorrect ID
- 220 Vmain
- 221 Timeout
- 222 Test Vmain
MENU 4 INDICATIONS
OK
OK
OK
OK
41 TIME LOSS
4
WARNINGS
42.....................79
80 NON STANDARD
PROGRAM.
The display shows current alerts:
- 41 Date and time loss
- 42 Clock battery flat or absent
- 44 Emergency active
- 45 TIMER active (indicated with T in HOME PAGE)
- 46 Timer function in progress
- 47 Last motion run with battery
- 48 Night-time mode operation
- 49 Manual mode operation
- 50 Partial mode operation
- 51 Obstacle in closing
- 52 Obstacle in opening
- 53 Number of maintenance cycles corrupted on E2prom
- 54 Motor block fault
- 55 Pharmacy mode operation
- 56 Battery operation
- 57 Searching for strike on opening
- 58 Searching for strike on closing
- 59 Motor block anomaly (only with monitoring KIT)
- 60 Requested maintenance
- 61 SDK EVO anomaly
- 62 Faulty battery charger

Table of Contents

Related product manuals