A1400 AIR RDT 62 532119 04 - Rev. C
TX1
RX1
T1 G
T2
R1
G R2
TX2
RX2
TX1
RX1
T1 G
T2
R1
G R2
84
85
+ RX2
GND
+ RX1
+ TX2
GND
+ TX1
J9
+ R2
GND
+ R1
+ T2
GND
+ T1
E1 G E2
E1 G E2
E1 G E2
E1 G E2
J7
J7
86
J7
J7
+24V
V G 01 02 02
J22
87
Translation of the original instructions
ENGLISH
12.11 J9 BUTTON PHOTOCELLS XFA
!
The photocells are not admitted as safety devices in European Com-
munity countries where the EN 16005:2012 standard is in force.
Specifically, photocells are considered as auxiliary devices, comple-
mentary to safety.
In extra-European countries where the EN 16005:2012 standard is
not in force, it is possible to continue using traditional photocells
and sensors.
Button photocells are constantly monitored by the door’s control
electronic board, which controls correct operation at each movement.
Connect the photocells and enable them in programming (
bP)
84 or 85.
NO PHOTOCELL - If no button photocells are used, leave J9 connector
inputs free and program the function
bP =
no.
The number of photocells may be programmed by SDK EVO.
12.12 J7 EMERGENCY: REMOTE OPENING
The EMERGENCY control has priority over any other input, in any
operating condition and mode, except MANUAL operation.
activation of the EMERGENCY command with busy safety on opening
is executed up to the PO % set at the max. speed. The remaining space
is executed in LOW ENERGY mode.
The emergency causes the door to OPEN, and it remains open as long
as the control is kept active.
1. Connect a NO or NC type double contact button
2. Enable input for the type of contact (
E1).
With SDK EVO, emergency operation may be programmed with
several options.
J22 CONFIGURABLE OUTPUTS
V G 01 02 02
J22
O2 Output2 configurable relay output (programming)
O2 Output2 configurable relay output (programming)
O1 Output1 configurable (programming)
G GND Accessories power supply negative and Common contacts
V
+24V
accessories power supply
With SDK EVO, O1 and O2 operation on J22 may be programmed
with several options.
O1 and O2 specifications:
- O1 Open Collector output with Max load 100mA to be connected between 01 and V.
- O2 relay contact with Max load 2A to be connected between O2 and O2.
CABLE colour
TX - transmitter grey and blue (grey sheath)
RX - receiver black and blue (black sheath)
1 pair of button photocells
bP =
1
2 pairs of button photocells
bP =
2
E1 =
nO (NO input)
E1 =
nC (NC input)
1 button
1 button
2 buttons
2 buttons
blueblue
blue
blue
blue
blue
blackblack
black
grey
grey
grey
black
black
black
grey
grey
grey
J9
NO/NC Relay Contact