A1400 AIR RDT 54 532119 04 - Rev. C
Translation of the original instructions
ENGLISH
J13  MOTOR BLOCK AND MONITORING OPTIONALS
J13
Connection of motor block with monitoring (OPTIONALS)
J14  EMERGENCY BATTERY
!
Installation of the battery is obligatory since it is an essential safety
component.
IMPORTANT: charge the battery before starting up the system.
In this stage, if the battery is flat operation is prevented: only SETUP
may be performed.
When the battery is flat, only setup may be performed; upon comple-
tion the door remains open and error10 is displayed.
The board maintains battery charge, but does not charge batteries
when flat.
To check charge status see LEDs DL5 and DL6 (52).
J14
Emergency battery connection
J17  USB PORT
J17
Connection of the USB memory device
J18  NOT USED
J21  CONFIGURABLE INPUTS
V
G
I1
I2
G
I3
I4
V
J21
V
+24V
accessories power supply
I4 Input4 configurable (programming)
I3 Input3 configurable (programming)
G GND Accessories power supply negative and Common contacts
I2 Input2 configurable (programming)
I1 Input1 configurable (programming)
G GND Accessories power supply negative and Common contacts
V
+24V
accessories power supply
J22  CONFIGURABLE OUTPUTS
V G 01 02 02
J22
O2 Output2 NC/NO configurable relay output (programming)
O2 Output2 NC/NO configurable relay output (programming)
O1 Output1 configurable (programming)
G GND Accessories power supply negative and Common contacts
V
+24V
accessories power supply
J23 J24 J25  OPTIONAL MODULES
J23
Module connection
G-COM / WI-COM / Net-COM
J24
J25

Table of Contents