A1400 AIR RDT 91 532119 04 - Rev. C
Translation of the original instructions
ENGLISH
- External n.c. CONTACT
- External no CONTACT
- Internal current
- Internal frequency
- External current
- External frequency
5 Emergencies E1 / E2
1. Select input E1. The complete list with relevant default is:
- E1 Opening /NO
- E2 Opening /NO
Input E2 is non modifiable and performs the function set for E1.
2. Select function:
- Opening with memory
- Opening
- Disabled
3. If the input is enabled, select the logic:
- Normally open (NO)
- Normally closed (NC)
6 XFA Photocells
XFA Photocell inputs are disabled by default.
1. Select:
- Disabled
- 1 pair
- 2 pairs
2 MOTION
OK
OK
MOTION
2
PROGRAMMING
Opening
Choose and modify the parameter. The complete list with relevant
default and range of values is:
- 1 SPEED 10 (from 1 to 10)
- 2 SLOWDOWN 1 cm (from 0 to 200)
SLOWDOWN SPEED 1 (1-3)
- 3 FORCE 10 (non modifiable)
- 4 FORCE TIME 3.0s (cannot be modified)
- 5 ACCELERATION 10 (from 1 to 10)
- 6 DECELERATION 10 (from 1 to 10)
Closing
Choose and modify the parameter. The complete list with relevant
default and range of values is:
- 1 SPEED 3 (from 1 to 10)
- 2 SLOWDOWN 1 cm (from 0 to 2(00)
SLOWDOWN SPEED 1 (1-3)
- 3 FORCE 6 (from 1 to 10)
- 4 FORCE TIME 1.0s (from 0.1 to 3.0)
- 5 ACCELERATION 6 (from 1 to 10)
- 6 DECELERATION 6 (from 1 to 10)
- 7 INVERSION(*) 5 (from 1 to 5 )
* the INVERSION parameter determines the inversion speed of the
leaf in the closing stage with 5 level setting from 1 (slow) to 5 ( fast).
3 TIMING
OK
OK
TIMING
2
PROGRAMMING
Choose and modify the parameter. The complete list with relevant
default and range of values is:
- 1 PAUSE TIME 2s (0-30)
- 2 NIGHT PAUSE TIME 10s (0-240)
- 3 NIGHT SENSOR DELAY 10s (0-240)
4 ENERGY SAVING
OK
OK
ENERGY SAVING
2
PROGRAMMING
The Energy Saving is disabled by default. Available options are:
- ENABLED
- DISABLED
5 BATTERY KIT
OK
OK
BATTERY KIT
2
PROGRAMMING
Defines the automations behaviour with emergency battery, in case of
mains power outage. The options with relevant default are as follows:
- 1 FUNCTION (Immediately last mov.)
- 2 LAST MOVEMENT (Opening)
- 3 NIGHT-TIME FUNCTION (Up to the last motion) (Default)
Selectable: Now last motion
- 4 NIGHT-TIME LAST MOTION (Closure) (Default)
Selectable: Opening
These settings are non modifiable.
If the door is in NIGHT-TIME, battery operation is not active.
6 MOTOR BLOCK KIT
OK
OK
MOTOR LOCK KIT
2
PROGRAMMING
Defines motor block behaviour (OPTIONAL accessory).
The options with relevant default are as follows:
- 1 TYPE
- 2 FUNCTION (Disabled)
- 3 MONITORING KIT (Disabled)
- 4 BATTERY OPERATION (NIGHT-TIME)
1 TYPE
Defines the type of motor block:
- XB LOCK
- XM LOCK
2 FUNCTION
Defines operating methods in which motor block is activated;
- Disabled
- Night
- Night-time + Open
3 MONITORING KIT
Enables/disables monitoring on motor block;
- ENABLED
- DISABLED
If the monitoring kit (OPTIONAL accessory) is not installed, disable.
4 BATTERY OPERATION
Defines battery operation of the motor block:
- STANDARD: the operation selected is maintained even with
battery.
- NIGHT-TIME: motor block active only in NIGHT-TIME mode.
- ALWAYS OPEN: motor block always OPEN