Port and network services used by the inverter
IP Network Services
Any network connected to the inverter must allow traffic to pass on the following ports. Network
firewall rules (if present) must allow responses to the inverter over existing TCP connections.
Direction Service/Port Protocol Description
In ssh/22 Tcp
For local debugging by FIMER service
personnel, the inverter utilizes encrypted SSH.
To allow service personnel local access to the
inverter.
Out domain/53 Tcp/udp
The inverter must be able to resolve domain names, to
ensure scalability and dynamic changes on the Internet
(DNS). (required)
Out https/443 Tcp
As an HTTP client, the inverter uses SSL/TLS protocol
connections to Aurora Vision
®
servers for secure
communication. The inverter uses this port for all services,
including data transmission, firmware upgrade, configuration
management, and remote command transmission.
(required)
Out
dh cp /67,
dhcp/68
Udp
If DHCP service is not available, static network information
must be assigned to the inverter (preferred)
Out ntp/123 Udp
The inverter uses this port for network time services (NTP).
(preferred)
Out
modbus/502
Tcp
The inverter offer a Modbus TCP server connection on this
port.
Out
dns-sd/5353
Udp
The inverter uses this protocol to resolve the local IP
address.
Out
http/80
Tcp
As an HTTP client, the inverter uses this protocol to offer
local connection.