Maintenance Instructions
18.12.15 Kapitel/Chapter 7: Maintenance Instructions - Seite/Page 115
7.3 Environmental protection
Environmental protection.Danger to the environment due to mishandling!
Significant environmental damage can occur, particularly for
incorrect disposal, if environmentally hazardous operating
materials are mishandled. Therefore:
Always observe the instructions mentioned below.
Take immediate action if environmentally hazardous
materials reach the environment. Inform the responsible
local authorities about the damage in the case of doubt.
The disposal must be performed by a specialist disposal company.
7.4 Maintenance interval
For the maintenance interval, please see the „General information for PMS generators“ which are attached to this
manual.
At generator with dynamic operation hours (f.e. Generators with iControl2 system) the maintenance interval can may
be extended.
Note:With the dynamic operation hours the service interval can be
raised up to 30 % (200 h max.). Make sure that the dynamic
operation hours are not reset accidently between the service
interval.
7.5 General maintenance instructions
7.5.1 Checks before each start
• Oil level
Leaks in the Cooling system
Visual check for any changes, leaks in the oil drain system, v-belt, cable connections, hose clips, air filter, fuel lines
Once a month
Grease/oil the servo motor - Trapezoid thread-spindle
Maintenance intervals - see separate data sheet
7.5.2 Check of Hoses and rubber parts in the sound insulated capsule
Check all hoses and hose connections for good condition. The rubber hoses are very sensitive to environmental
influences. They wear out quickly in an environment of dry air, oil and fuel vapours, and high temperatures.
The hoses must be checked regularly for elasticity. There are operating situations, when hoses must be renewed
once a year.
Additionally to usual tasks of maintenance (oil level check, oil filter control etc.) further maintenance activities are to
be accomplished for marine generators, such as control of the sacrificial anode (cooling water connection block) and
the front seal cover at the generator.