Installation Instructions
18.12.15 Kapitel/Chapter 6: Installation Instructions - Seite/Page 65
6.5 Installation of the cooling system - fresh water
6.5.1 Position of the external cooling water expansion tank
Fig. 6.5.1-1: Position of the external cooling water expansion tankPosition of the external cooling water expansion tank
The Panda generator is normally supplied with an additional,
external cooling water expansion tank. This tank must be
installed in such a way that its lower edge is at least 200 mm
more highly arranged than the highest point of the Generator.
If this 200 mm should be fallen below, i.e. the cooling water
expansion tank is lower installed, very large problems can
occur with filling and ventilating. Extend and displace the
hose lines to the outside or possibly even up to the deck.
ATTENTION!The external cooling water expansion tank may be filled
only up to the lower edge of the lower tension tape (see
note „max“) in the maximum filling level in cold
condition.