11.4.3 Starting the generator
Warning! Automatic startDanger for life! - The generator can be equipped with a
automatic start device. This means the generator can be
started by an external signal. To avoid an unexpected
starting of the generator, the starter battery must be
disconnected before start working at the generator.
Fig. 11.4.3-1: Panel on1. Switch the xControl CP-G on
Wait till the overview screen appear
Fig. 11.4.3-2: Start2. Press the Start/Stop - Enter button
Fig. 11.4.3-3: Self test3. The xControl will make a self test.
Fig. 11.4.3-4: Pre glow4. The xControl pre glow the generator engine
After the pre glow the engine will be started by the xControl.