Maintenance Instructions
18.12.15 Kapitel/Chapter 7: Maintenance Instructions - Seite/Page 157
Fig. 7.16.1-4: Impeller pump
Pull to the impeller with a multigrip pliers of the wave.
Mark the impeller, to make sure that these is used in the
correct position at re-installation.
Representative picture
Fig. 7.16.1-5: ImpellerCheck to the impeller for damage and replace it if
necessary.
Before the reinsertion into the housing the impeller should
have been lubricated with glycerin or with a non-mineral oil
based lubricant e.g. silicone spray.
The impeller is attached to the pump wave (if the old impeller
is used, pay attention to the before attached marking).
Representative picture
Fig. 7.16.1-6: GasketFastening the cover and use a new seal.
Representative picture
7.17 Check and discharge the capacitors
Attention!:NEVER check the capacitors whilst the generator motor
is running! Charged capacitors can be lethal. Do not
contact the capacitors with bare fingers or non-insulated
metallic objects! In order to test the capacitors, the
terminal lead wires have to be disconnected using pliers
or a screwdriver with insulated handle(s). Once the wires