EasyManua.ls Logo

Fluke DTX-MFM2 - Page 287

Fluke DTX-MFM2
320 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Maintenance and Specifications
Specifications
13-33
13
Loss/Length Specifications (cont.)
-continued-
Specification
DTX-MFM2
Multimode Modules
DTX-GFM2
Gigabit Modules
DTX-SFM2
Singlemode Modules
Length measurement accuracy ± 1.5 m plus ± 2 % of length
Propagation time accuracy ± 15 ns plus ± 2 % of propagation time
Output power (nominal) -20 dBm -7 dBm -7 dBm
Output power stability over 8-hour
period (after 5 minute warmup)
± 0.10 dB over 8 hours, 5
minute warm-up time
± 0.25 dB over 8 hours, 5
minute warm-up time
± 0.25 dB over 8 hours, 5
minute warm-up time
Detector type InGaAs
Calibrated wavelengths 850 nm, 1310 nm, 1550 nm
Power measurement range 850 nm: 0 dBm to -52 dBm
1300/1310 nm, 1550 nm: 0 dBm to -60 dBm
Display Resolution dB, dBm: 0.01
Linear (μW): >400, >40, >4, >0.4, 0.4: 1, 0.1, 0.01, 0.001, 0.0001

Table of Contents

Other manuals for Fluke DTX-MFM2

Related product manuals