EasyManua.ls Logo

Fluke DTX-MFM2 - Page 288

Fluke DTX-MFM2
320 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DTX Series CableAnalyzer
Technical Reference Handbook
13-34
Loss/Length Specifications (cont.)
Specification
DTX-MFM2
Multimode Modules
DTX-GFM2
Gigabit Modules
DTX-SFM2
Singlemode Modules
Power measurement uncertainty (accuracy)
± 0.25 dB
1
Measurement linearity
(18 °C to 28 °C constant temperature)
1300/1310 nm and 1550 nm: ±0.1 dB
2
850 nm: ±0.2 dB
3
Dynamic Range for main-remote
communication and nominal length
measurement
12 dB 22 dB 22 dB
Re-calibration period 1 year
Display update rate 1 reading per second
1. Under the following conditions:
Power level: -20 dBm, continuous wave
At 850 nm: 62.5/125 μm fiber with 0.275 NA
At 1310 nm and 1550 nm: 9 /125 μm
Ambient temperature: 23
o
C ±5
o
C
2. Linearity for 1310 nm and 1550 nm:
Between 0 dBm and -55 dBm: ± 0.1 dB
< -55 dBm: ± 0.2 dB
3. Linearity for 850 dBm:
Between 0 dBm and -45 dBm: ± 0.2 dB
< -45 dBm: ± 0.25 dB