OMNISCANNER User Guide
• Setup Projects
• View Graphs
• Edit Autotest information
The following sections provide detail on the certification process.
Setting the Reference
A reference must be set when OMNISCANNER and OMNIREMOTE are used
as a set for the first time. After the initial reference setting, the process
should be repeated periodically to ensure unit verification.
OMNISCANNER stores reference data for up to 5 remote units by serial
number.
1. To set the reference, connect OMNISCANNER
and OMNIREMOTE using the PERMANENT LINK
ADAPTER and CHANNEL ADAPTER supplied
with the scanner (as shown).
2. Turn OMNISCANNER on.
3. Press (Setup).
4. Select Set Reference.