3 - 5
OMNISCANNER User Guide
The Adapter: field will automatically change
to reflect that OMNIFIBER is currently attached.
OMNISCANNER auto-senses the adapter. If the
adapter is changed, OMNISCANNER will auto-
matically adjust the content in the fields
Autotest: and Cable: to reflect the new
setup.
Every Project has certain Autotests and cables
assigned already. These associated lists will
appear in the pop-up lists for each item. If the Autotest or Cable you
want to use is not in a pop-up list, open (Setup) to select the
appropriate item. (See Chapter 4 - Setup: Autotest, Cable, or Project
for further information.)
Running an Autotest for Fiber Optic Cabling
Preparing an Autotest
Connect OMNIFIBER MAIN to the near end of the RX/TX fiber pair you are
testing and connect OMNIFIBER REMOTE to the far end. Depending on the
method that was used to obtain the reference, connect your fibers as
follows:
2 JUMPER METHOD AUTOTEST
To run an Autotest when the 2-Jumper Method was used to set the
Reference proceed as follows:
1. Do not disconnect the launch cables from the OMNIFIBER.
2. Remove the connector sleeves that connect the two launch cables.
3. Connect the OMNIFIBER MAIN to one end of the duplex link under test,
and the OMNIFIBER REMOTE to the opposite end.
2 m Launch Cable
2 m Launch Cable
Patch Panel
Wall Plate
Cable under Test