5 - 13
OMNISCANNER User Guide
Power Sum ACR
Power Sum ACR is calculated from the Attenuation of the disturbing
pair subtracted from the Power Sum NEXT for the pair. The worst case
Power Sum ACR is reported for each pair.
The POWER SUM ACR screen displays the pairs in
the column on the left side, followed by the
PSACR in decibels (dB), the margin/limit, and the
frequency. The result for each pair is tagged with a
PASS or FAIL indicator.
Press or to toggle between Power
Sum ACR results for OMNISCANNER and OMNIREMOTE.
Press (Graph) to view the graph for the
currently highlighted pair. Attenuation and
PSNEXT are displayed for the frequency indicated
by the cursor position.
Press (Pairs) to view Attenuation and PS
NEXT graphs for other pairs.
Press ESC to exit the POWER SUM ACR screen.