OMNISCANNER User Guide
4 - 12
Press ESC to discard all changes and return to the SETUP screen.
Autotest Save Options
Select Autotest Save Options to display the SAVE OPTIONS screen.
This screen contains several options that allow you to customize the
way OMNISCANNER will save Autotests.
Press ENTER to change the Destination: from MMC
(MultiMediaCard
TM
) to Internal. Use the éê keys to highlight the
desired destination and press ENTER to select it as the default destina-
tion.
Select MMC if you want to collect test results on
the MultiMediaCard, or select MMC (Auto
Save) if you want the results to be saved on the
MultiMediaCard automatically after the test has
been completed. (See Chapter 11 - MultiMedia-
Card for more information about MMC.)
Select Internal if you want to save the results to
OMNISCANNERs internal memory, or select Inter-
nal (Auto Save) if you want the results stored
automatically after a test has been completed.
In either case, results can be transferred to the Scanlink
TM
Tools soft-
ware program. (See Chapter 9 - Uploading and Printing for more
information.)
In the Save Graph Options section you will be able to define which
of the graphs will be saved.
Note
This options is not available when performing coaxial Autotests.
If a checkbox is checked , OMNISCANNER will store an Autotest with
the graph information for that particular test.
Note
Saving graphs reduces the number of Autotest that can be stored.
Depending on the performed Autotest, NEXT/PSNEXT, ELFEXT/-
PSELFEXT, Return Loss, and Attenuation graphs can be saved.
Use the éê to highlight the Save Graph Option checkboxes.